the 'official' hybrid assembly homepage


the table

Hybrid-number action batch notes
30216711300255 sent to UCSB
30216711300262 sent to UCSB
30216711300286 sent to UCSB
30216711300301 sent to UCSB
30216711300321 sent to UCSB

change of parameters by end of the week

we are doing some statistics to figure out the values for the absolute (RMSmin, RMSmax) and relative (TBad) cuts There will be a decision by the end of the week.

our 13 parameters used so far to test hybrids WITHOUT PA: (Feb. 03)

Raw Data: number of events: 5000
pedestal&noise Tbad 55
RMSmin 0.3
RMSmax 1.2
Tskip 54
Pskip 0.2
number of events: 5000
pipeline as before, except in
number of events 60
pulse shape max Latency 19
min Latency 9
max Latency (Dec) 18
min Latency (Dec) 14
Remarks:
max, min Latency (Dec) not applied yet
with 50 and 60 events in pipeline, sometimes 1 pipeline cell with noise 0

 